Purecell™ Select System for Whole Blood MNC Enrichment
Rapid, easy-to-use, filter-based technology for the enrichment of mononuclear cells
Pall’s novel Purecell Select System revolutionizes the enrichment of mononuclear cells (MNC) with a new filtration-based platform that is fast, easy to use, and produces consistently high cell recoveries. The system frees scientists from traditional lab-based methodologies such as density gradient centrifugation that are known to be time consuming and labor intensive.- Accelerated processing – Achieve enrichment of MNC from 20 to 120 mL of whole blood in 15 minutes or less.
- Easy to use – Simply transfer the sample to the sample input bag, filter the sample, then back-flush the Harvest Solution through the filter, collecting the enriched MNC in a collection bag. During the filtration process, the majority of the plasma, red blood cells, and platelets pass through the filter into the waste bag below. The MNC are captured on the filter and released during the back-flush process with the optimized Harvest Solution. No capital equipment or special training is required.
- Consistent results – With the Purecell Select System, the uniquely designed filter and optimized Harvest Solution do all the difficult cell separation work. This results in a highly robust process with consistent results, critical when working with highly variable biologic samples. Using a filtration-based platform minimizes operator training and variability between operators, resulting in a more predictable cell yield.
- Higher cell recovery – MNC recovery from 50 mL whole blood consistently averages > 70%. The Purecell Select System consistently recovers 20 to 50% more MNC than Ficoll* processing.
- Increased level of safety – The risk of sample contamination and biohazard exposure is reduced in this smart-set design by incorporating needleless access ports and eliminating open-tube processing.
For research use only. Not for human use.
![]() |
![]() |
*Ficoll is a trademark of GE Healthcare companies.
Smart-set Design
The consistent performance and usability of the Purecell Select System has been thoughtfully engineered. The Purecell Select System combines a number of unique design features including:
- Filter materials that capture and release the cells of interest
- Filter housing that ensures a reliable media seal and optimal flow characteristics
- Single-use set that incorporates Pall’s easy-to-use bag technology
- Valve ports that engage with luer fittings to eliminate the need for needles
- Optimized Harvest Solution to maximize cell recovery
- Add sample
- Filter
- Recover MNC

Purecell Select System Advantage
For many applications, the easy-to-use Purecell Select System can replace centrifugation-based gradient methods and thus, the technician manipulations those methods demand. This translates to:
- Consistently higher recoveries of MNC.
- Improved ease of use, reducing processing steps and processing variables.
- Fast processing in 15 minutes or less.
- A sterile fluid path for filtration and separation with no open-tube processing step, minimizing the opportunity for contamination.
Sample Type
Human whole blood or cord bloodAnticoagulants
Compatible with all commonly-used anticoagulants (although EDTA is not recommended)Sample Volume
20 mL - 120 mLOperating Temperature
Room temperatureMaterials of Construction
Bags: Medical-grade PVCFilter: Medical-grade acrylic and polyester
Tubing and Connectors: Medical-grade PVC
Fittings and Valves: Medical-grade polycarbonate and medical-grade silicone
Biological Safety
All materials meet safety and biocompatibility requirementsSterilization
Filter Harvest Set, Syringes, and Adapters: Gamma irradiationHarvest Solution: Sterile filtration
Dimensions
Set Length (fully assembled): 58.42 cm (23 in.)Set Width (fully assembled): 20.32 cm (8 in.)
Kit Box: 33.0 cm x 15.2 cm x 5.6 cm (13 in. x 6 in. x 2.2 in.)
Six-pack Case: 34.3 cm x 32.4 cm x 17.5 cm (13.5 in. x 12.8 in. x 6.9 in.)
Storage Conditions
Room temperatureShelf Life
12 monthsTraceability
Lot numberRegulatory
Research use only; not for human useSingle use and disposable with a sterile and non-pyrogenic fluid path
Manufacturing
Manufactured in accordance with current Good Manufacturing Practices (cGMP) requirementsTo order outside the USA, contact your local Pall office:
Australia - Cheltenham, VIC
Tel: 03 9584 8100
800 635 082 (in Australia)
Fax: 1800 226 825
Brazil - Rio de Janeiro
Tel: (5521) 2111.92.08
Fax: (5521) 2111.92.05
Canada - Ontario
Tel: 905-542-0330
800-263-5910 (in Canada)
Fax: 905-542-0331
Canada - Québec
Tel: 514.332.7255
800.435.6266 (in Canada)
Germany - Dreieich
Tel: 06103.307.333
Fax: 06103.307.399
India - Mumbai
Tel: +91 22 67995555 or +91 22 66830700
Fax: +91 22 67995556
Korea - Seoul
Tel: 82.2.560.8711
Fax: 82.2.569.9095
Thailand - Bangkok
Tel: (66) 2937 1055
Fax: (66) 2937 1066
United Kingdom - Portsmouth
Tel: +44 (0)23 9230 3452
Fax: +44 (0)23 9230 3324
Biosvc@Pall.com
United States - Michigan
Tel: 734.665.0651
800.521.1520 (in USA and Canada)
Fax: 734.913.6495
Stem_Cells@Pall.com
Technical Application Notes - Read the Detailed Data
- Performance Characterization of the Purecell™ Select System for Enrichment of Mononuclear Cells from Human Whole Blood (PN33505)
- Flexible Purecell™ Select System Enables Protocol Modifications to Optimize Enriched MNC Population for Downstream Applications (PN33506)
- Hematopoietic Progenitor Cells from Whole Blood Processed with the Purecell™ Select System (PN33507)
- Umbilical Cord Blood CD34+ Cell Selection and Expansion Using Mononuclear Cells Enriched by the Purecell™ Select System (PN33536)
A Quick Look at This Fast, High-Yield Alternative to Traditional Density Gradient Centrifugation
Pall’s Purecell Select System is an alternative technology to density gradient centrifugation for the enrichment of MNC from whole blood or cord blood. Many density separation media are available commercially, of which Ficoll-Paque* is the most widely used.
Pall’s filtration-based system provides researchers with an alternative enrichment technology that is significantly faster than traditional methods and results in a higher cell yield than Ficoll separations. The MNC recovery from the Purecell Select System typically averages > 70% (Figure 1). MNC recovery across the WB volume range processed by the Pall system (20 to 120 mL) typically averages > 65% (data not shown).
Percent Recovery of Major Leukocyte Populations

Percent recovery of major cell types in 50 mL WB starting material, Purecell Select System processed samples and Ficoll samples. Percent recovery is calculated based on WBC, platelet and red blood cell (RBC) concentration (Cell-Dyn* 1800); percent lymphocytes, monocytes and granulocytes is based on phenotype data (BD FACSCalibur system). Duplicates are averaged. Means +/- 1 SD from 6 donors are reported.
Phenotypic analysis of processed samples shows that the Purecell Select System yields more cells of all major types than are recovered with Ficoll separations (Figure 2). The cell population from the Purecell Select System differs from the cell population recovered from Ficoll in that the cell population from the Pall system has a higher concentration of granulocytes and red blood cells. Researchers will need to assess the specific requirements of their applications. Protocol modifications can reduce the residual red blood cell concentration.Total Cell Number of Major Leukocyte Populations

Total number of major cell types in 50 mL WB and processed samples. Phenotype data (BD FACSCaliber system) averages from 6 donors +/- 1 SD are reported.
Cell viability at 24 hours using propidium iodide is comparable to cell viability from Ficoll processing.Viability of WBC Population
| WB | Purecell Select System | Ficoll |
| 95.7% +/- 1.5 | 96.0% +/- 1.4 | 97.3% +/- 3.2 |
Percent viability of white blood cells (WBC) was determined by dye exclusion using propidium iodide. The percent viability was calculated by the percentage of unstained versus total cells as determined by flow cytometry (BD FACSCalibur* system). N=5.
*Ficoll and Ficoll-Paque are trademarks of GE Healthcare companies. Cell-Dyn is a registered trademark of Abbott Laboratories. BD FACSCalibur is a trademark of BD Biosciences.
Contact Customer Service at 800-521-1520 for possible lead-time and ship date.
|
Your shopping cart is empty. |
| *US List Price applies only to products delivered within the US. These prices do not reflect duties, taxes or tariffs, which may apply to purchases made outside of the US. See our General Limited Warranty. |