Glass Fiber Filters
Superior Grade Filters for a Variety of
Biological and Environmental Methods
- Type A/E meets the requirements for suspended solids testing, as described in Standard Methods for the Examination of Water and Wastewater, current edition.
- Reduces filtration costs and premature clogging when filtering difficult-to-filter or highly contaminated solutions.
- Extends filter life and reduces final filter changes with high capacity prefilters.
- Eliminates sample contamination. Binder-free borosilicate glass fiber has no added extractables.
- Filters a wide range of particulate loads and viscous solutions with a selection of filter thicknesses from which to choose.
- Filters with binder offer excellent wet strength for easy handling and filter integrity.
Used in a variety of sample clean-up, prefiltration, and analytical testing applications. Choose between binder-free borosilicate glass for complete purity or glass fiber with acrylic binder for added strength.
Type A/E Glass Fiber
- For testing dissolved and suspended solids in wastewater and gravimetric analysis of air pollutants.
- High flow rates, wet strength, and dirt (solids) holding capacities.
Type A/B Glass Fiber
- High dirt-loading capacity with 2.5 times thicker glass than Type A/C.
- Manufactured of the highest quality borosilicate glass microfibers.
Type A/C Glass Fiber
- For testing dissolved and suspended solids in wastewater.
- Useful for cell harvesting applications.
- Purity eliminates risk of unwanted contaminants leaching into the filtrate.
Type A/D Glass Fiber
- Excellent prefilters for solutions with a heavy load of large-sized particulate that must be removed.
- Large nominal pore size reduces membrane clogging.
Extra Thick Glass Fiber With Binder
- Preferred for prefiltration of viscous biological solutions.
- High particulate-holding capacity makes discs efficient depth filters and allows for filtration of large volumes of solutions.
Metrigard™ Glass Fiber With Binder
- Useful for prolonging membrane filter life in liquid systems that contain substantial amounts of particulate matter.
TCLP Glass Fiber
- Designed to meet requirements for use in U.S. EPA SW-846 Method 1311: Toxic Characteristics Leaching Procedure (TCLP).
Specifications and Selection Chart
| Description | Type A/E | Type A/B | Type A/C |
| Typical Applications | Water solids testing, air monitoring, gravimetric analysis |
Diagnostic applications, sample prefiltration |
Cell harvesting, prefiltration, solids testing |
| Filter Media | Borosilicate glass without binder | Borosilicate glass without binder | Borosilicate glass without binder |
| Pore Size (Nominal) | 1 μm | 1 μm | 1 μm |
| Typical Thickness | 330 μm (13 mils) | 660 μm (26 mils) | 254 μm (10 mils) |
| Typical Water Flow Rate mL/min/cm2 at 0.3 bar (30 kPa, 5 psi) |
250 | 124 | 153 |
| Typical Air Flow Rate L/min/cm2 at 0.7 bar (70 kPa, 10 psi) |
60 | 24 | 40 |
| Maximum Operating Temperature | Air - 550 °C (1,022 °F) | Air - 550 °C (1,022 °F) | Air - 550 °C (1,022 °F) |
| Sterilization | Autoclavable | Autoclavable | Autoclavable |
| Typical Aerosol Retention* | 99.98% | – | – |
| Description | Type A/D | Extra Thick Discs | Metrigard™ Discs | TCLP |
| Typical Applications with large-sized particulate |
Prefiltration of solutions contaminated samples |
Prefiltration of heavily | Prefiltration in systems with high particulate matter |
U.S. EPA Method 1311 |
| Filter Media | Borosilicate glass without binder |
Glass fiber with acrylic binder** |
Ultrafine glass fiber with acrylic binder** |
Borosilicate glass without binder*** |
| Pore Size (Nominal) | 3 μm | 1 μm | 0.5 μm | 0.7 μm |
| Typical Thickness | 660 μm (26 mils) | 1270 μm (50 mils) | 330 μm (13 mils) | 432 μm (17 mils) |
| Typical Water Flow Rate mL/min/cm2 at 0.3 bar (30 kPa, 5 psi) |
649 | 210 | 80 | – |
| Typical Air Flow Rate L/min/cm2 at 0.7 bar (70 kPa, 10 psi) |
139 | 26 | 21 | – |
| Maximum Operating Temperature | Air - 550 °C (1,022 °F) | Water - 135 °C (275 °F) | Water - 135 °C (275 °F) | Water - 135 °C (275 °F) |
| Sterilization | Autoclavable | Autoclavable | Autoclavable | Autoclavable |
| Typical Aerosol Retention* | – | 99.97% | – | – |
* Following ASTM D 2986-95A 0.3 μm (DOP) at 32 L/min/100 cm2 filter media.
** Binder is 5% of total material.
*** TCLP glass fiber filters are not acid washed.
Contact Customer Service at 800-521-1520 for possible lead-time and ship date.
|