AcroPak™ 500, 1000, & 1500 Capsules with Supor® Membrane
Fast, final filtration and high throughputs for liquid volumes up to 150 liters
- Provides higher throughputs and faster flow rates than similarly-sized competitive devices.
- Ideal for solutions requiring low protein binding.
- Saves money by increasing throughput with available built-in prefilter.
- 100% integrity testing assures sterile filtrate.
- 0.1 µm Supor membrane version ensures sterile, mycoplasma-free cell culture media.
- Fusion-welded components eliminate the potential for release of extractables from sealing adhesives.
- Sterilization by gamma irradiation eliminates potential contamination by EtO residuals.
- Large-volume media preparation
- Pilot-scale manufacturing
- Liquids requiring prefiltration, such as serum-containing media
- Sterile filtration of buffers
- Point-of-use filtration for laboratory water
- Reduce mycoplasma with the 0.1 µm pore size
Materials of Construction
Filter Media: Supor membrane (hydrophilic polyethersulfone)Housing, Vent Plug, and Filter Support: Polypropylene
Sealing Technology: Thermal bonding
Filling Bell: Polycarbonate
Pore Size
0.1/0.1, 0.2/0.2, 0.8/0.2 and 0.8/0.45 µm
Effective Filtration Area
500 Series: 500 cm21000 Series: 1000 cm2
1500 Series: 1500 cm2
Dimensions
Diameter: 6.9 cm (2.7 in.)Overall Length (without Filling Bell):
500 series: 14.5 cm (5.7 in.)
1000 series: 19.3 cm (7.6 in.)
1500 series: 22.9 cm (9.0 in.)
Inlet/Outlet Connections
500 & 1000 Series:6.4 - 12.7 mm (1/4 - 1/2 in.) stepped hose barb with filling bell on outlet
1500 Series:
12.7 mm (1/2 in.) straight hose barb, no filling bell on outlet
Typical Hold-up Volume(with 10 psi air purge)
500 series: 30 mL1000 series: 45 mL
Maximum Operating Temperature
60 °C (140 °F) at 2.1 bar (210 kPa, 30 psi)Maximum Operating Pressure
Continuous: 4.1 bar (410 kPa, 60 psi) at ambient temperatureRecommended Integrity Test
Minimum Bubble Point – Water
0.2 µm: 3.5 bar (350 kPa, 51 psi)0.45 µm: 1.7 bar (170 kPa, 24 psi)
60% IPA/40% H2O (v:v)
0.1 µm: 2.4 bar (240 kPa, 35 psi)
Typical Water Flow Rate
Lpm at 0.1 bar (10 kPa)[Lpm/psi]:
| 500 Sereis | 1000 Sereis | 1500 Series | |
| 0.1/0.1 µm | 0.2 (0.2) | 0.4 (0.3) | |
| 0.2/0.2 µm | 0.6 (0.4) | 1.1 (0.8) | 1.6 (1.1) |
| 0.8/0.2 µm | 1.1 (0.8) | 1.6 (1.1) | 2.2 (1.5) |
| 0.8/0.45 µm | 1.3 (0.9) | 2.5 (1.7) | |
Bacterial Retention
0.1/0.1 µm capsules: Lot samples retain a minimum of 107 cfu/cm 2 of A. laidlawii challenge per modified ASTM F838-83, current revision0.2 µm capsules: Lot samples retain a minimum of 107 cfu/cm2 of B. diminuta per modified ASTM F838-83, current revision
Endotoxin Level
< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) testBiological Safety
Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>Sterilization
Sterilized by gamma irradiation. If desired, autoclave once only prior to use at 121 - 123 °C (250 - 253 °F) for a maximum of 20 min.Total Throughput Recorded for Devices with an EFA of Up to 1000 cm2
.jpg)
Throughput Determined using 3% TSB
Built-in Prefilter Enhances Total Throughput

Membrane Type: 47 mm Disc
Throughput Determined using 2.5 % TSB
Contact Customer Service at 800-521-1520 for possible lead-time and ship date.
|