Jumbosep™ Centrifugal Devices
Convenient and Reliable Concentration, Purification, and Diafiltration
- Concentration, purification, and diafiltration of 20 to 60 mL biological samples
- Typically concentrates 60 mL sample volumes to 5 mL in 30 minutes
- Provides high recoveries, typically > 90%
- Low protein-binding Omega™ membrane and polysulfone housing minimize losses due to non-specific binding
- Versatile Omega membrane is available in a variety of MWCOs, color-coded for easy identification
- Built-in deadstop prevents spinning to dryness
- Unique sealing mechanism prevents retentate leakage and filtrate contamination
- Economical - Sample reservoir and filtrate receiver can be sanitized or autoclaved, and reused
Replaces dialysis, chemical precipitation, and lyophilization in the following applications:
- Concentrating and desalting proteins
- Exchanging buffer or removing salt from chromatography eluates and gradient fractions
- Separating biomolecules from cell culture supernatants
- Concentrating or removing viruses
- Performing crude fractionation of protein mixtures
- Removing debris and particulates from cell lysates
Materials of Construction
- Filter Media: Omega (modified polyethersulfone) membrane
- Sample Reservoir and Filtrate Receiver: Polysulfone
- Sample Reservoir Cap: Polyethylene
- Insert Without Membrane: High density polyethylene
- Filtrate Receiver Cap and Insert Release: Polypropylene
Effective Filtration Area
- 15.2 cm2
Dimensions
- Outside Diameter (Maximum): 6 cm (2.4 in.)
- Overall Height (Fully Assembled with Cap): 11.3 cm (4.5 in.)
Capacities
- Maximum Sample Volume: 60 mL
- Final Concentrate Volume: 3.5 - 4 mL
- Maximum Filtrate Receiver Volume: 60 mL
- Hold-up Volume (membrane/support): 0.2 mL
Operating Temperature Range
- 0 - 40 °C (32 - 104 °F)
pH Range
- 1 - 14
Centrifuge
- Swinging bucket rotor is required that accepts flat-bottomed 250 mL bottles and is capable of spinning at up to 3,000 x g
Sanitization
- Provided non-sterile. The entire device, including the filter media, may be sanitized by filtering 70% ethanol through it prior to use. The sample reservoir and the filtrate receiver can be autoclaved. Do not autoclave the filter media.
- BioTrace™ NT Nitrocellulose Transfer Membrane
- BioTrace™ PVDF Transfer Membrane
- Biodyne® Transfer Membranes
- Macrosep® Advance Centrifugal Devices
- Macrosep® Centrifugal Devices
- Microsep™ Advance Centrifugal Devices
- Microsep™ & Microsep MF Centrifugal Devices
- Nanosep® & Nanosep MF Centrifugal Devices
- UltraBind™ Affinity Membrane
Jumbosep™ Device Reduces Processing Time Over Other Devices



1 mg/mL BSA solution was processed in each of the above devices until a 15-fold concentration is achieved.
Concentration Time
Concentrate dilute protein samples in less than 30 minutes with 10, 30, and 100K Jumbosep devices.
Contact Customer Service at 800-521-1520 for possible lead-time and ship date.
|
Your shopping cart is empty. |
| *US List Price applies only to products delivered within the US. These prices do not reflect duties, taxes or tariffs, which may apply to purchases made outside of the US. See our General Limited Warranty. |