Strong, chemically resistant membranes for air monitoring and sampling in aggressive environments
- Low chemical background permits highly sensitive, interference-free determinations.
- Ensures accurate gravimetric determinations with low tare mass.
- Zefluor™ membrane now available in 0.5 µm pore size to meet NIOSH specifications.
- Ideal for filtration of gas and/or organic solvents.
- For air monitoring and sampling in aggressive environments.
- Supported membranes offer increased durability for hostile testing environments or acid aerosol monitoring.
- Teflo membrane offers unique PMP support ring for PM 10 and PM 2.5 dichotomous and other air sampling techniques.
- Ultimate in chemical compatibility for filtering harsh chemicals and HPLC mobile phases that destroy other membrane materials.
|
| Description |
Zefluor Membrane |
Teflo Membrane |
|
|
|
| Filter Media/Support |
PTFE with PTFE support |
PTFE with PMP (polymethylpentene) support ring |
|
|
|
| Typical Thickness |
0.5 µm: 178 µm (7 mils) 1 µm: 165 µm (6.5 mils) 2 and 3 µm: 152 µm (6 mils) |
1 µm: 76 µm (3 mils) 2 µm: 46 µm (1.8 mils) 3 µm: 30.4 µm (1.2 mils) |
|
|
|
Typical Air Flow Rate (L/min/cm2 at 0.7 bar (70 kPa, 10 psi)) |
0.5 µm: 1 1 µm: 14.6 2 µm: 25.3 3 µm: 53 |
1 µm: 17 2 µm: 53 3 µm: 90 |
|
|
|
| Minimum Bubble Point - IPA bar (psi) |
Not Applicable |
Not Applicable |
|
|
|
|
Water Breakthrough bar (psi) |
Not Applicable |
Not Applicable |
|
|
|
| Typical Aerosol Retention* |
0.5, 1, and 2 µm: 99.99% 3 µm: 99.98% |
1 and 2 µm: 99.99% 3 µm: 99.79% |
|
|
| Description |
Zylon Membrane |
TF (PTFE) Membrane |
|
|
|
| Filter Media/Support |
Unsupported PTFE |
PTFE on a polypropylene support |
|
|
|
| Typical Thickness |
140 µm (5.5 mils) |
0.2 µm: 139 µm (5.5 mils) 0.45 and 1 µm: 135 µm (5.3 mils) |
|
|
|
Typical Air Flow Rate (L/min/cm2 at 0.7 bar (70 kPa, 10 psi)) |
5 µm: 13 |
0.2 µm: 2 0.45 µm: 3 1 µm: 7 |
|
|
|
Minimum Bubble Point - IPA bar (psi) |
Not Applicable |
0.2 µm: 1.0 (15) 0.45 µm: 0.4 (6) 1 µm: 0.1 (2) |
|
|
|
Water Breakthrough bar (psi) |
Not Applicable |
0.2 µm: 2.8 (40) 0.45 µm: 1.1 (16) 1 µm: 1.0 (15) |
|
|
|
| Typical Aerosol Retention* |
Not Applicable |
Not Applicable |
|
*Following ASTM D 2986-95A 0.3 µm (DOP) at 32 L/min/100 cm2 filter media.
Contact Customer Service at 800-521-1520 for possible lead-time and date item will be available to ship.
|
 |
Your shopping cart is empty.
|
|
*US List Price applies only to products delivered within the US. These prices do not reflect duties, taxes or tariffs, which may apply to purchases made outside of the US. See our General Limited Warranty.
|
|